Tech Note G802-13: AISI S100 Section A2.2 Other Steels
$5.00
Summary: AISI S100, Section A2.1, Applicable Steels, provides a list of pre-qualified steels that can be used without restriction. The Specification also permits steels that are not listed in Section A2.1 to be used without re-striction. This Tech note provides specific examples to demonstrate how to implement Section A2.2, Other Steels.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.
Related Products

Tech Note F502-18: Attachment of CFS Framing to Precast, Post-Tensioned, and Hollow-Core Concrete
Summary: Precast, prestressed, tilt-up, cast-in-place, and post-tensioned concrete are commonly used in podium construction. It is inevitable that the cold-formed steel design engineer will sooner or later be challenged with attaching cold-formed steel framing to podium construction. Towards this end, it is important for the designer to have a basic understanding of common precast concrete components and why connecting to them can be such a challenge. This Tech Note discusses the types of precast concrete components as well as the cold-formed steel anchorage options.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note F102-21: Screw Fastener Selection For Cold-Formed Steel Frame Construction
Summary: Specifying the proper fastener is necessary to assure the proper performance of the connections used in cold-formed steel construction. Cold-formed steel connections primarily utilize externally threaded fasteners, so embedment is not the controlling parameter. Instead, the design of the fastener along with the thickness of the steel govern the value of the connection. This Tech Note provides basic information for determining the appropriate screw type for various applications.
This Technical Note updates and replaces CFSEI Tech Note F102-11
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note F501-11: Cold-Formed Steel Truss To Bearing Connections
Summary: This Technical Note is intended as general educational information and to highlight what the building designer should be aware of with regard to truss to bearing connections. Topics addressed include what loads due to wind truss to bearing connections may have to resist, who is ultimately responsible for truss to bearing connection design, general guidance on the design of truss to bearing connections, and an illustrative design example. Loads due to seismic forces are not addressed in this Technical Note.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note B002-20: How Cold-Formed Steel is Used in Building Construction
Summary: Cold-formed steel framing is used in numerous applications across the building industry. The purpose of this Technical Note is to provide a general overview of common cold-formed steel shapes and various applications in which they are used.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note B010-21: Introduction to AISI S202, Code of Standard Practice for Cold-Formed Steel Structural Framing
Summary: Understanding the responsibilities of the different parties involved in a cold-formed steel framing project can be confusing. This Technical Note is an introduction to AISI S202, Code of Standard Practice for Cold-Formed Steel Structural Framing published by the American Iron and Steel Institute (AISI).
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note D200-12: Corrosion Protection for Cold-Formed Steel Framing in Coastal Areas
Summary: Cold-formed steel framing may be subject to corrosion when exposed to moisture and salt, both of which are prevalent in coastal areas. The 2003 edition of this technical note, based on guidelines published by the Federal Emergency Management Agency (FEMA 1986) for metal connectors used in wood-framed construction, described the cause of accelerated corrosion in buildings located near the ocean and some larger saltwater bays, as well as the variation in the corrosive environments within a typical building. The 2007 update incorporated the results of a corrosion study by Dr. Ian Robertson of the University of Hawaii Department of Civil Engineering, funded by the U.S. Department of Housing and Urban Development (SFA 2006). The influence of terrain and wind direction on corrosion rates was added to the original document. This 2012 update includes revised referenced documents and improved guidance on the proper storage of materials. This technical note outlines available corrosion-resistant materials for cold-formed steel framing members
and makes recommendations for buildings at various distances from the ocean and for different exposure conditions within an individual building.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note D001-13: Durability of Cold-Formed Steel Framing Members
Summary: The purpose of this document is to give engineers, architects, builders and home and commercial building owners a better understanding of how galvanizing (zinc and zinc alloy coatings) provides long-term corrosion protection to cold-formed steel framing members. This document also suggests guidelines for selecting, handling and using these steels in framing applications.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note F101-12: Screws for Cold-Formed Steel-To-Wood and Wood-To-Cold-Formed Steel Attachments
Summary: Screws are often used to attach cold-formed steel (CFS) framing to wood members or wood structural panel decking to CFS joists or rafters. The AISI North American Specification for the Design of Cold-Formed Steel Structural Members (AISI S100) provides design equations for screw connection capacity for CFS members. The National Design Specification for Wood Construction (NDS) provides design equations for fastener/connection capacity (nails, wood screws, bolts, etc.) in wood members. The Engineered Wood Association (APA) and the building codes offer several resources for determining the capacity of screw connections attaching wood sheathing. This Tech Note reviews these resources and discusses design and detailing of these fastener connections.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.