Tech Note W200-26: Header Design
$30.00
This Tech Note Updates and Replaces Tech Note W200-23
Summary: AISI S240, North American Standard for Cold-Formed Steel Structural Framing provides provisions needed to design headers over door and window openings in buildings. AISI S240 Section B3.3 – Header Design reflects the appropriate design procedures for back-to-back headers, box headers, and Single, Double and Inverted L-headers subject to gravity loads or wind uplift loads. This Technical Note provides additional recommendations and design examples intended to supplement the AISI S240 header provisions.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.
Related Products

Tech Note G100-23: Using Chapter K of the North American Specification for the Design of CFS Structural Members
This Tech Note Updates and Replaces Tech Note G100-07
Summary: The North American Specification for the Design of Cold-Formed Steel Structural Members is intended for use throughout the U.S., Canada and Mexico and was developed by the American Iron and Steel Institute, Canadian Standards Association, and CANACERO in Mexico. The Specification provides procedures for the design of load bearing cold-formed steel members in buildings and certain other applications.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note B010-21: Introduction to AISI S202, Code of Standard Practice for Cold-Formed Steel Structural Framing
Summary: Understanding the responsibilities of the different parties involved in a cold-formed steel framing project can be confusing. This Technical Note is an introduction to AISI S202, Code of Standard Practice for Cold-Formed Steel Structural Framing published by the American Iron and Steel Institute (AISI).
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note T201-20: Firestops in Head-of-Wall Joints for Cold-Formed Steel Construction
Summary: The selection of fire-resistive joint systems is aided by an abundance of listed options. This same abundance can make it difficult to find the fire-resistive joint system that not only meets project requirements but also the most project-friendly. Firestop manufacturers conduct training programs for installing contractors, architects, building officials, and others who would like to learn more about fire-resistive systems. Specialty firestop contractors can help with understanding project-specific opportunities. Both UL and FM offer certification programs for firestop contractors to help ensure consistency across the industry. Moreover, it is important to note whether a project will require special inspection of firestops systems. For example, 2018 IBC, Section 1705.17, lists requirements for special inspection of firestops in certain high-rise buildings. There are companies that focus on offering special inspection services. For recommendations or further learnings, please contact your firestop provider. The firestop industry is focused on improving life safety in the built environment through improved passive fire protection.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note D001- 23: Durability of Cold-Formed Steel Framing Members
This Tech Note Updates and Replaces Tech Note D001-13
Summary: The purpose of this document is to give engineers, architects, builders and home and commercial building owners a better understanding of how galvanizing (zinc and zinc alloy coatings) provides long-term corrosion protection to cold-formed steel framing members. This document also suggests guidelines for selecting, handling, and using these steels in framing applications.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note W101-23: Common Design Issues for Deflection Track
This Tech Note Updates and Replaces Tech Note W101-09
Summary: When cold-formed steel studs are used on exterior walls between spandrel beams or floor slabs to create the exterior envelope of the building, a deflection track is often required at the top of the wall to allow for the roof or floor above to deflect without transferring axial load to the studs. This Technical Note explores two methods for deflection track usage. Additional design guidance is provided in CFSEI Tech Note W100, Single Slip Track.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note T202-20: Thermal Energy Transfer of Cold-Formed Steel Framing
Summary: While the concepts of energy conservation and efficiency are not new, the demand for sustainable building is at an all-time high. Energy efficiency, and more specifically thermal energy transfer in steel stud construction, presents the construction team with a clear opportunity for reduction in thermal bridging. Advanced analysis of building thermal simulation through scientific thermal modeling programs illustrates that the construction team has the ability to significantly reduce thermal transfer. Use of cold-formed steel framing with a reduced thermal bridging area, in combination with increased spacing of the framing system provides, among other benefits, a significant and positive impact on thermal performance.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note 551e: Design Guide: Permanent Bracing of Cold-Formed Steel Trusses
Summary: Prefabricated and site fabricated cold-formed steel trusses have proven to be efficient and structurally-sound roof structures. While roof trusses are the major component of the structural roof system, permanent bracing is also required to complete the system and ensure that it performs as designed. In this Tech Note, the basic requirements and design parameters for permanent bracing of cold-formed steel roof systems will be reviewed.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note F100-23: Design of Clip Angle Bearing Stiffeners
Summary: Clip angles are commonly used in cold-formed steel constructions to attach floor joists to the rim track. Clip angles can also work as bearing stiffeners to reinforce the web crippling strength of the floor joists at the bearing locations. As the length of the clip angle may significantly influence the floor joist web crippling strength, it is critical to ensure the minimum length of the clip angle in design.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.