Tech Note F602-26: Screw Connections with Other Materials or Gaps Between the Plies
$30.00
This Tech Note Updates and Replaces Tech Note F602-20
Summary: Screws are the most common connection type for connecting cold-formed steel members to one another. It is also common for gaps to be provided between members in the form of other materials such as gypsum or insulation, but unfortunately, the current standards do not provide clear direction for the design of screwed connections with gaps in the material. This Tech Note will summarize available test data and propose design guidance based on the available test data.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.
Related Products

Tech Note L002-23: Strap Braced Wall: Loose Strap Considerations
Summary: Strap braced walls are a common means of providing lateral stability for cold-formed steel load-bearing structures. Discussed in this technical note are causes of loose straps, potential stability implications as well as potential means of remediation.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note F100-23: Design of Clip Angle Bearing Stiffeners
Summary: Clip angles are commonly used in cold-formed steel constructions to attach floor joists to the rim track. Clip angles can also work as bearing stiffeners to reinforce the web crippling strength of the floor joists at the bearing locations. As the length of the clip angle may significantly influence the floor joist web crippling strength, it is critical to ensure the minimum length of the clip angle in design.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note D100-23: Corrosion Protection of Fasteners
This Tech Note Updates and Replaces Tech Note D100-13
Summary: Moisture, airborne chemicals and pollutants can all combine to reduce the life of ferrous fasteners through corrosion. This Technical Note examines the corrosion process, available fastener finishes, methods of measuring corrosion and the relative durability of fastener finishes.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note B010-21: Introduction to AISI S202, Code of Standard Practice for Cold-Formed Steel Structural Framing
Summary: Understanding the responsibilities of the different parties involved in a cold-formed steel framing project can be confusing. This Technical Note is an introduction to AISI S202, Code of Standard Practice for Cold-Formed Steel Structural Framing published by the American Iron and Steel Institute (AISI).
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note T201-20: Firestops in Head-of-Wall Joints for Cold-Formed Steel Construction
Summary: The selection of fire-resistive joint systems is aided by an abundance of listed options. This same abundance can make it difficult to find the fire-resistive joint system that not only meets project requirements but also the most project-friendly. Firestop manufacturers conduct training programs for installing contractors, architects, building officials, and others who would like to learn more about fire-resistive systems. Specialty firestop contractors can help with understanding project-specific opportunities. Both UL and FM offer certification programs for firestop contractors to help ensure consistency across the industry. Moreover, it is important to note whether a project will require special inspection of firestops systems. For example, 2018 IBC, Section 1705.17, lists requirements for special inspection of firestops in certain high-rise buildings. There are companies that focus on offering special inspection services. For recommendations or further learnings, please contact your firestop provider. The firestop industry is focused on improving life safety in the built environment through improved passive fire protection.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note 551e: Design Guide: Permanent Bracing of Cold-Formed Steel Trusses
Summary: Prefabricated and site fabricated cold-formed steel trusses have proven to be efficient and structurally-sound roof structures. While roof trusses are the major component of the structural roof system, permanent bracing is also required to complete the system and ensure that it performs as designed. In this Tech Note, the basic requirements and design parameters for permanent bracing of cold-formed steel roof systems will be reviewed.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note F102-21: Screw Fastener Selection For Cold-Formed Steel Frame Construction
This Technical Note updates and replaces CFSEI Tech Note F102-11
Summary: Specifying the proper fastener is necessary to assure the proper performance of the connections used in cold-formed steel construction. Cold-formed steel connections primarily utilize externally threaded fasteners, so embedment is not the controlling parameter. Instead, the design of the fastener along with the thickness of the steel govern the value of the connection. This Tech Note provides basic information for determining the appropriate screw type for various applications.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.

Tech Note 562-22: Powder-Actuated Fasteners in Cold-Formed Steel Construction
This Technical Note updates and replaces Tech Note 562
Summary: Power-actuated fasteners (PAF’s) are industry standard for attachment of cold-formed steel (CFS) steel framing members, usually track, to concrete, CMU or steel structural elements. “Power-actuated” is the broad category used to refer to fasteners which are driven directly through the CFS and into the substrate, using a powder, gas, compressed air or electro-mechanically driven tool. Efficient installation of framing systems is greatly enhanced by the use of PAF’s. For CFS-to-steel applications, the specification AISI S100 addresses all relevant limit states with equations and safety/ resistance factors. For CFS-to-concrete, limited guidance is provided but not all limit states are covered. This technical note will provide design guidance based on AISI S100, as well as installation and good detailing practice.
Disclaimer: Designs cited herein are not intended to preclude the use of other materials, assemblies, structures or designs when these other designs demonstrate equivalent performance for the intended use. CFSEI documents are not intended to exclude the use and implementation of any other design or construction technique.